ProSAFE Plus switches are configured using the UM+ utility installed on a MS Windows based computer.

When the UM+ utility starts, it will detect and display the ProSAFE Plus switches in the network.

If the UM+ utility cannot detect the ProSAFE Plus switch,

  1. Make sure there is network connectivity from the computer to the ProSAFE Plus switch.
  2. Some firewall software installed on the computer may prevent the UM+ utility to detect the ProSAFE Plus switch. Try disabling the firewall software.
  3. Some software such as VPN client software may prevent the UM+ utility to detect the ProSAFE Plus switch. Try to disable or uninstall the software.
  4. If the ProSAFE Plus switch is either FS116E or JFS524E and the UM+ utility was able to detect the switch right after the UM+ utility was installed but cannot detect the switch anymore after the computer reboot, the WinPcap (NPF) driver being used in the UM+ utility may not get started correctly.

To workaround the issue, user may manually configure the NPF driver to start automatically at system start using one of the following three procedures:

  • From the Device Manager you can select View->Show hidden devices, then open Non-Plug and Play Drivers and right click NetGroup Packet Filter Driver. In the driver properties you can set the startup type as well as start and stop the driver manually.
  • From the command line you can run:
    sc config npf start=auto
    (This must be run as Adminstrator under Vista)
  • In the registry, you can change:
    HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\NPF\Start from 0x3 (SERVICE_DEMAND_START) to 0x2 (SERVICE_AUTO_START) or 0x1 (SERVICE_SYSTEM_START).

 

 

Last Updated:07/07/2025 | Article ID: 12344