Enterprise AV Home WiFi Mobile Wifi Support Shop Deals

New Features and Enhancements:

  • Add FEC configuration command to configure CL74 or CL91(CL108) options for fiber modules.
  • Support 25G port speed using 25GBase-LR modules
  • Provided mechanism to retain custom applications and their configuration during ONIE image upgrade.

Bug Fixes:

  • Device cannot assign detached port to port-channel interface.
  • DNS query doesn’t work in Linux shell
  • SNMP can’t get PSU & FAN data
  • Flow control can't work properly in some port speed.
  • Executing Set/no port-monitor for range of interfaces continuously caused the device to popup an error log: "This interface cannot be configured as source port."
  • Setting port mirror causes double packets to be received at destination port.
  • Device crashes when power cycle command is executed.
  • Device  pops out an error message when binding "gt/lt/neq/range" rules for TCP/UDP ports on an interface in outbound direction.
  • The packets loss occurs when ISSU is executed and firmware is uploaded via Linux.
  • Device crashes and console port gets hung when playing 4K video for a long time over MLAG interface.
  • Device crashes while executing power cycle.
  • Service port flaps unexpectedly. Need BMC version 3.05 or firmware version 7.0.0.14 to make the service port to work properly.
  • Plugging in AGM734 SFP module without connecting any cable shows the  port status as link-up
  • SNMP walk and SNMP get-next cannot work  
  • Change the cli-command-log display sequence
  • Modify the prompt string of MAC address in service-port status/info
  • Device shows error when try to get BMC information via telnet or SSH session
  • Management VLAN can't get ip address from DHCP server if service port gets IP address first
  • Device shows physical status as null when physical port is configured for lower speed.
  • Console hangs when "show logging traplogs” is issued.
  • When serviceport protocol is set  to none, save and reload the device, then running-config will show it as "serviceport ip 0.0.0.0 0.0.0.0 0.0.0.0
  • If port speed is different from the transceiver then link status is not down.
  • Port count is wrong on M4500-48XF8C. The correct number is 136, not 352.
  • IP source guard configuration, “ip verify source”, disappears after the switch reboots when both “ip verify source” and “ip verify source port-security” are configured.
  • Techsupport file should not be deleted after copying the file to TFTP has failed
  • Fast-leave disabled interface will clear all IGMP entries in multi-device scenario.
  • Switch clears all IGMP entries when it receives only one IGMP leave on port-channel interface.
  • [Multicast traffic can't be forwarded using IGMPv3 group when “sdvoe <Vlan> enable” is configured.
  • IGMPv3 "include/Exclude" filter mode doesn’t work

Known Issues:

  • In 7.0.0.14 release use of 10G copper transceiver module AXM756 on M4500-48XF8C may cause the system to hang. If the system hangs, “pca953x 19-0021: failed reading register” message is seen on the console. As a workaround remove AXM756 module and reboot the system.

Download Link : http://www.downloads.netgear.com/files/GDC/M4500/M4500-48XF8C-7.0.0.16.zip

Firmware Update Instructions:

To update your product’s firmware, follow the instructions in your product’s user manual. To find your user manual, visit https://www.netgear.com/support/, enter your model number in the search box, and click the Documentation button on the product page.

Last Updated:07/07/2025 | Article ID: 000061576

This article applies to:

Recently Viewed Articles

    Our team is here to help!

    Phone
    Chat
    Email