SNMP type Sub type Trigger condition
FAN   If the fan speed is greater than or less than a threshold value, ReadyNAS get the minimum value via sensors_get_value function.
Temperature   1. System temperature exceeded safety threshold
2. Auxiliary temperature exceeded safety threshold
3. CPU temperature exceeded safety threshold
Power Voltage   This is not used
Disk Event   Disk status changed to FAILED/UNAVAIL/OFFLINE/UNKNOWN 
Snapshot Event   1. Snapshot was successfully deleted from share or LUN
2. Failed to remove records for snapshot from share or LUN
3. Snapshot was successfully created for share or LUN
4. Failed to create snapshot for share or LUN
5. Snapshot was deleted from share or LUN due to low free space on the volume
6. Snapshot monitor failed to delete Snapshot from the home directory of user
7. Snapshot was deleted from the home directory of user due to low free space on the volume
8. Snapshot monitor failed to delete Snapshot from the home directory of user
9. Snapshot prune worker successfully deleted snapshot from share or LUN
10. Snapshot prune worker failed to remove records for snapshot from share or LUN
11. Share or LUN was successfully rolled back to snapshot
12. Share or LUN failed to roll back from snapshot
13. Snapshot was successfully cloned to share or LUN
14. Snapshot failed to clone to share or LUN
15. Manual snapshot was deleted from share or LUN due to low free space on the volume
16. Continuous protection snapshot count dropped to 60 in volume
17. Continuous protection is no longer protecting data in volume. Continuous protection on this volume will automatically resume as scheduled when enough space is available
Hotplug Disk   1. Disk was added to Channel of the expansion unit
2. Disk was added to Channelof the head unit
3. Disk does not meet the minimum required capacity to resync the volume
4. Disk was removed from Channel of the expansion unit
UPS Event   1. On line power
2. On battery power
3. Battery is low. System will shut down soon (This threshold is set by user)
4. Forcing shutdown  (This threshold is set by user)
5. Communication with UPS is OK
6. Error communicating with UPS
7. Battery error. Replace the battery
8. Cannot communicate with UPS
9. UPS is shutting down the system
Volume Event Disk operation 1. Successfully made disk on channel a global spare disk
2. Failed to make disk on channel a global spare disk
3. Disk format failed on channel
4. Disk format completed on channel
Bit Rot 1. Bit rot protection detected an error on the disk and corrected the error
2. Bit rot has detected an error within the file and cannot correct the error
Metadata tier migration 1. Metadata tier migration started for volume
2. Metadata tier migration failed to start for volume
3. Metadata tier migration completed for volume
Data tier migration 1. Data tier migration started for volume
2. Data tier migration failed to start for volume
3. Data tier migration completed for volume
Scrub 1. Scrub started for volume
2. Scrub stopped for volume
3. Scrub completed for volume
4. Scrub is in process for volume
5. Scrub failed to start for volume
Disk test 1. Disk test failed to start for volume
2. Disk test is in process for Volume
3. Disk test started for volume
4. Disk test completed for volume
5. Disk test failed on disk
SSD trim 1. SSD trim started for volume
2. SSD trim failed to start for volume
3. SSD trim complete for volume
4. Cannot start SSD trim for volume while another SSD trim is in progress
Balance 1. Balance started for volume
2. Balance failed to start for volume
3. Balance complete for volume
Defragmentation 1. Defragmentation started for volume
2. Defragmentation complete for volume
Other 1. Volume was added to the system
2. Volume creation failed
3. Volume was deleted from the system
4. Volume deletion failed
5. Volume was exported from the system because volume health changed to unavailable
6. Volume export failed
7. Volume health has been changed
8. Failed to expand volume
9. Failed to change permission and ownership of the share
10. Successfully changed permission and ownership of the share
11. To mix different disk types
12. The volume encountered an error and was made read-only
13. Less than 70/80/90/95% of volume capacity is free
14. The data on the highest tier is exceeding its capacity for volume
15. The metadata on the highest tier is exceeding its capacity for volume
16. Lower tier is now full and the data on the highest tier is not able to migrate the data for volume
17. System volume usage is larger than 80%
18. Failed to start the service for volume since the volume is already running this server
19. Failed to activate encrypted volume
20. Home folders are newly created on volume
21. System will be shut down in 30 minutes because of disk failure.
22. Resyncing started for Volume
23. Pending shutdown cancelled due to resync operation on volume
24. The resync operation finished on volume
25. Volume is resynced
26. Volume configuration was switched to Flex-RAID
27. Volume configuration was switched to XRAID
28. Remove RAID group failed for volume
29. Remove RAID group complete for volume
30. Remove RAID group started for volume
31. The volume configuration has been migrated to the new tiering option to provide you the best performance. ReadyNAS OS started a balance operation for volume  to complete the migration.
Disk Temperature   This is not used
Backup Event   1. Successfully completed Backup button jobs
2. Cancelled backup job
3. Errors occurred during backup
4. Backup button job is in progress
5. MTP Device connected and preparing backup
6. Automatic MTP backup started
7. Automatic MTP backup completed successfully
8. ReadyDR job failure
9. ReadyDR Job completed successfully
Disk Smart Detected increasing reallocated sector count on disk 1. 50 reallocated sectors AND power-on hours <= 24
2. Reallocated sector count increasing at least 10 times in the past 30 days AND reallocated sector count > 500
3. Reallocated sector count > 1500
Detected increasing spin retry count 1. Greater than 50 spin retries
2. 10 or more spin retries in the past 30 days
Detected increasing end-to-end errors 1. Greater than 25 end-to-end errors
2. 10 or more  end-to-end errors in the past 30 days
Detected increasing command timeouts 1. Greater than 25 command timeouts
2. 10 command timeouts in the past 30 days
Detected pending sector count 1. 50 pending sectors AND power-on hours < 24
2. Pending sector count increasing at least 10 times in the past 30 days AND pending
3. Pending sector count > 500
Detected uncorrectable errors 1. Greater than 25 uncorrectable errors
2. 10 uncorrectable errors in the past 30 days
Detected increasing ATA errors 1. ATA error count has increased more than 10 times in the past 30 days
2. ATA error count has increased more than 100 in the past 30 days
PSU Event   1. Power supply in enclosure is no longer detected
2. Power supply in enclosure is offline
System Event Application 1. Application is installed. Reboot to complete the installation
2. Application was uninstalled successfully
3. Application was uninstalled. Reboot to complete the uninstallation
4. Cannot install application
5. Application is installing. Wait until installation is complete
6. Application is not ready for installation, but will be ready in the near future
Antivirus 1. Antivirus scanner found a threat
2. Antivirus scanner definition file was updated
3. Antivirus scanner definition file update failed due to download failure
Bluetooth 1. External Bluetooth adapter connected
2. External Bluetooth adapter disconnected
3. Bluetooth connection established by client
4. Bluetooth connection disconnected by client
5. The Bluetooth connection has timed out, and Bluetooth has been deactivated
6. Bluetooth connection idle timed out
7. Bluetooth connection pairing code
8. Bluetooth pairing was successful with client
UPS 1. The new UPS detected
2. UPS removed
External storage 1. External storage device connected
2. External storage device disconnected
3. External storage device is connected but the file system is not recognized
Other Alert message failed to send