NOTE:
CUSTOMERS UPGRADING CONTROLLER FROM 6.0.1.X FIRMWARE MUST UPGRADE TO THE MIGRATION FIRMWARE (6.0.1R.0) FIRST BEFORE UPGRADING TO 6.5.3.9 RELEASE
Customer having WAC720, WAC730, In the Controller network:
- Upgrade the controller to 6.0.1R.0 firmware which is bundled together with 6.5.3.9 release zip file.
- Once the upgrade is complete login to the controller, and make sure that all the APs have come to the connected state.
- Customer MUST wait for at least 15 minutes after all APs have come to connected state.
- After waiting for 15 minutes, upgrade the controller to 6.5.3.9 firmware.
- Once the upgrade is complete login to the controller and make sure all the APs have come to connected state, clients are able to connect to the network, and the controller network is up and running.
| Current Firmware Version | Upgrade Steps |
| WC7500-6.0.1.X | 6.0.1.X -> 6.0.1R.0 -> 6.5.3.9 |
Customer not having WAC720, WAC730 in the controller network:
- Customer not having 720, 730 in the controller network don’t need to go through the migration firmware release. They can directly upgrade the controller from 6.0.1.x to 6.5.3.9
| Current Firmware Version | Upgrade Steps |
| WC7500-6.0.1.X | 6.0.1.X -> 6.5.3.9 |
Bug Fixes:
- Fixed Security Vulnerabilities in Web GUI.
- Increased performance, voice and video quality when using Zoom Pro video conferencing.
- Increased throughput performance on WAC720/WAC730/WAC740 when managed with the WLAN controllers WC7500, WC7600, WC7600V2 and WC9500.
Upgrade Matrix:
Upgrade to 6.5.3.9 from recent releases
| Devices | Firmware Upgraded From below versions to 6.5.3.9 |
| WC7500 | 6.5.3.7 |
| WC7500 | 6.5.3.5 |
| WC7500 | 6.5.3.4 |
| Older Firmware Version | Upgrade Steps |
| WC7500-6.5.3.7 | 6.5.3.7 -> 6.5.3.9 |
| WC7500-6.5.3.5 | 6.5.3.5 -> 6.5.3.9 |
| WC7500-6.5.3.4 | 6.5.3.4 -> 6.5.3.9 |
Upgrade to 6.5.3.9 from Standalone/ Cloud AP Firmware
The following table lists the minimum Standalone AP firmware version required before they can be discovered and converted to the Controller firmware. Customer has to downgrade to the same standalone AP firmware version, if they have to manage the AP in standalone mode.
Note: Make sure SNMP is enabled on the following models before discovery process in controller.
| AP Model | Firmware Version |
| WNAP210 | 3.7.4.0 |
| WNAP320 | 3.7.4.0 |
| WNDAP350 | 3.7.4.0 |
| WNDAP360 | 3.7.4.0 |
| WNDAP660 | 3.7.4.0 |
| WAC720 | 3.7.11.0 |
| WAC730 | 3.7.11.0 |
| WAC740 | NOT APPLICABLE |
| WND930 | 2.1.2 |
Upgrade Instructions:
- Using the Download Link below, download and extract the new firmware to a convenient place such as your desktop.
Download Link: http://www.downloads.netgear.com/files/GDC/WC7500/WC7500_V6.5.3.9.zip - Log into the WC7500.
- Make a backup of the current running configuration from Maintenance > Backup/Restore and select BACKUP button.
**Read the Caveats below if the upgrade is from a lower major release - Select Maintenance > Upgrade from the main/submenu.
- In the Firmware Upgrade section, select Local File and click Browse.
- Locate the downloaded file and click Apply.This will start the software upgrade to your WC7500. This may take some time. Do not interrupt the upgrade process. At the conclusion of the upgrade, your WC7500 will reboot.
- In case of stacked and redundancy configurations, please follow the below steps:
- Upgrade the redundant controller first if available. Wait for the redundant controller to upgrade successfully and come back active.
- Then upgrade in the order Secondary 2, Secondary 1 and Primary controller.
Caveats:
When the upgrade is from 4.x.x.x to 5.x.x.x and Admin password has any special characters (example:"P !@#$%^" ),change the password to alphanumeric only before upgrade (example : "Password"). Make a configuration backup, and upgrade. After the upgrade you can configure your old password again in 5.x.x.x.
Discovering Standalone from controller
| AP Model | Minimum AP software version |
| WNAP210v2 | V2.1.6 or later |
| WNAP320 | V2.1.6 or later |
| WNDAP350 | V2.1.9 or later |
| WNDAP360 | V2.1.12 or later |
| WNDAP620 | V2.0.8 or later |
| WNDAP660 | V2.0.5 or later |
| WAC720 | V3.1.1.0 or later |
| WAC730 | V3.1.1.0 or later |
| WNDAP930 | V2.0.4 or later |
This product includes software code developed by third parties, including software code subject to the GNU General Public License ("GPL") or GNU Lesser General Public License ("LGPL"). As applicable, the terms of the GPL and LGPL, and information on obtaining access to the GPL Code and LGPL Code used in this product, are available to you at NETGEAR Open Source GPL. The GPL Code and LGPL Code used in this product is distributed WITHOUT ANY WARRANTY and is subject to the copyrights of one or more authors. For details, see the GPL Code and LGPL Code for this product and the terms of the GPL and LGPL.