NOTE:
CUSTOMERS UPGRADING CONTROLLER FROM 5.5.1.X FIRMWARE MUST UPGRADE TO THE MIGRATION FIRMWARE (5.5.1C.0) FIRST BEFORE UPGRADING TO 6.5.1.11 RELEASE
Customer having WAC720, WAC730, In the Controller network.
- Upgrade the controller to 5.5.1C.0 firmware which is bundled together with 6.5.1.11 release zip file.
- Once the upgrade is complete login to the controller, and make sure that all the APs have come to the connected state.
- Customer must wait for at least 10 minutes after all APs have come to connected state.
- After waiting for 10 minutes, upgrade the controller to 6.5.1.11 firmware.
- Once the upgrade is complete login to the controller and make sure all the APs have come to connected state, clients were able to connect to the network, and the controller network is up and running
| Current Firmware Version | Upgrade Steps |
| WC7600-5.5.1.X | 5.5.1. X -> 5.5.1C.0->6.5.1.11 |
Customer not having WAC720, WAC730 in the controller network.
- Customer not having 720, 730 in the controller network don’t need to go through the migration firmware release. They can directly upgrade the controller from 5.5.1.x to 6.5.1.11.
| Current Firmware Version | Upgrade Steps |
| WC7600-5.5.1.X | 5.5.1.X -> 6.5.1.11 |
Bug Fixes from 6.5.1.8 to 6.5.1.11:
- Tunnel flap issues.
- WAC720, WAC730 AP reboot issues in a dense environment.
- Enabled the Japan DFS channels.
Upgrade Matrix:
Upgrade to 6.5.1.11 from recent releases
| Devices | Firmware Upgraded From below versions to 6.5.1.11 |
| 6.5.1.8 | |
| WC7600 | 6.5.1.2 |
| 5.5.X.X | |
| 5.1.0.X |
Upgrade procedure for Redundancy setup:
- Remove the redundancy, first upgrade the Secondary controller followed by the primary controller.
- Re-configure the redundancy.
Upgrade procedure for stack setup:
- First Upgrade the Secondary controllers followed by the primary controller.
Upgrade procedure for Stacked and Redundancy setup:
- Remove the redundancy, First Upgrade the Secondary controller followed by the secondary controllers and then primary controller.
- Re-configure the redundancy.
| Older Firmware Version | Upgrade Steps |
| WC7600-6.5.1.8 | 6.5.1.8 -> 6.5.1.11 |
| WC7600-6.5.1.2 | 6.5.1.2 -> 6.5.1.11 |
| WC7600-5.5.X.0 | 5.5.X.0 -> 5.5.1C.0 -> 6.5.1.11 |
| WC7600-5.1.0.x | 5.1.0.18 -> 6.5.1.11 -> 6.5.1.11 (double upgrade required) |
Note: The customers upgrading the controller firmware from 6.5.1.2 / 6.5.1.8 or 5.1.0.18 doesn’t need to go through the migration firmware release 5.5.1C.0.
Upgrade to 6.5.1.11 from Standalone AP Firmware
The following table lists the minimum Standalone AP firmware version required before they can be discovered and converted to the Controller firmware. Customer has to downgrade to the same standalone AP firmware version, if they have to manage the AP in standalone mode.
In firmware version 6.5.1.X we remove support for WNDAP620 model access point.
| AP Model | Firmware Version |
| WNAP210 | 3.5.23.0 |
| WNAP320 | 3.5.23.0 |
| WNDAP350 | 3.5.23.0 |
| WNDAP360 | 3.5.23.0 |
| WNDAP660 | 3.5.23.0 |
| WAC720 | 3.6.12.0 |
| WAC730 | 3.6.12.0 |
| WAC740 | NOT APPLICABLE |
| WND930 | 2.0.11 |
Upgrade Instructions:
- Using the Download Link below, download and extract the new firmware to a convenient place such as your desktop.
Download Link: http://www.downloads.netgear.com/files/GDC/WC7600/WC7600_FW_V6.5.1.11.zip - Log into the WC7600.
- Make a backup of the current running configuration from Maintenance > Backup/Restore and select BACKUP button.
**Read the Caveats below if the upgrade is from a lower major release - Select Maintenance > Upgrade from the main/submenu.
- In the Firmware Upgrade section, select Local File and click Browse.
- Locate the downloaded file and click Apply.This will start the software upgrade to your WC7600. This may take some time. Do not interrupt the upgrade process. At the conclusion of the upgrade, your WC7600 will reboot.
- In case of stacked and redundancy configurations, please follow the below steps:
- Upgrade the redundant controller first if available. Wait for the redundant controller to upgrade successfully and come back active.
- Then upgrade in the order Secondary 2, Secondary 1 and Primary controller.
Caveats:
When the upgrade is from 4.x.x.x to 5.x.x.x and Admin password has any special characters (example:"P !@#$%^" ),change the password to alphanumeric only before upgrade (example : "Password"). Make a configuration backup, and upgrade. After the upgrade you can configure your old password again in 5.x.x.x.
Discovering Standalone from controller
In firmware version 6.5.1.X we remove support for WNDAP620 model access point.
| AP Model | Minimum AP software version |
| WNAP210v2 | V2.1.6 or later |
| WNAP320 | V2.1.6 or later |
| WNDAP350 | V2.1.9 or later |
| WNDAP360 | V2.1.12 or later |
| WNDAP660 | V2.0.5 or later |
| WAC720 | V3.1.1.0 or later |
| WAC730 | V3.1.1.0 or later |
| WNDAP930 | V2.0.4 or later |
This product includes software code developed by third parties, including software code subject to the GNU General Public License ("GPL") or GNU Lesser General Public License ("LGPL"). As applicable, the terms of the GPL and LGPL, and information on obtaining access to the GPL Code and LGPL Code used in this product, are available to you atNETGEAR Open Source GPL. The GPL Code and LGPL Code used in this product is distributed WITHOUT ANY WARRANTY and is subject to the copyrights of one or more authors. For details, see the GPL Code and LGPL Code for this product and the terms of the GPL and LGPL.